Piping Systems and Applications! - Resources, Tools and Basic Information for Engineering and Design.
Maximum working pressure of cast iron pipe fittings - flanged fittings according ANSI B16.1.
Sponsored Links
The maximum working pressure of cast iron pipe fittings - flanged fittings according ANSI B16.1 can be found in the table below.
| Maximum Working Pressure (psig) | |||||
| Temperature (oF) | Pressure Class | ||||
| 125 | 250 | ||||
| Pipe Size (inches) | |||||
| 1 - 12 | 14 - 24 | 30 - 48 | 1 - 12 | 14 - 24 1) | |
| -20 up to 150 | 200 | 150 | 150 | 500 | 300 |
| 200 | 190 | 135 | 115 | 460 | 280 |
| 225 | 180 | 130 | 100 | 440 | 270 |
| 250 | 175 | 125 | 85 | 415 | 260 |
| 275 | 170 | 120 | 65 | 395 | 250 |
| 300 | 165 | 110 | 50 | 375 | 240 |
| 325 | 155 | 105 | - | 355 | 230 |
| 350 | 150 | 100 | - | 335 | 220 |
| 375 | 145 | - | - | 315 | 210 |
| 400 | 140 | - | - | 290 | 200 |
| 425 | 130 | - | - | 270 | - |
| 450 | 125 | - | - | 250 | - |
1) For liquid services - flanges only
Sponsored Links
Difficult to find your favorite ToolBox page? Add a link to the page in your own personal Shortlist!
Translate this page to
Spanish
French
German
Italian
Dutch
Norwegian
© The Piping ToolBox
The content in The Piping ToolBox is copyrighted but can be used with NO WARRANTY or LIABILITY. Important information should always be double checked with alternative sources. All applicable national and local regulations and practices concerning this aspects must be strictly followed and adhered to.
We appreciate any comments and tips on how to make The Piping ToolBox a better information source. Please contact us by email if You find any faults, inaccurate, or otherwise unacceptable information.
5 12 1
View Engineering, Design and Construction news in the absolute FREE Automatic WebSite Viewer. Engineering Breaking News!